Refco Powermax Manual do Utilizador Página 7

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 9
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 6
SELF EVACUATION
SET UP
1. CONNECT HOSES AS SHOWN BELOW.
2. CLOSE INLET VALVE (V1).
3. TURN CONTROL VALVE (V2) TO SELF-EVAC POSTION.
4. OPEN DISCHARGE VALVE (V3).
5. OPEN LIQUID VALVE ON THE RECOVERY TANK.
OPERATION
1. TURN POWER ON AND PRESS START BUTTON.
2. SUCTION GAUGE WILL THEN GO INTO A VACUUM.
3. SELF-EVACUATION PROCESS IS COMPLETED.
SHUT DOWN
1. CLOSE LIQUID VALVE ON RECOVERY TANK.
2. CLOSE DISCHARGE VALVE (V3).
3. TURN POWER SWITCH OFF.
6
VAPOR RECOVERY
SETUP
1. CONNECT HOSES AS SHOWN BELOW.
2. CLOSE INLET VALVE (V1).
3. TURN CONTROL VALVE (V2) TO RECOVER POSTION.
4. OPEN DISCHARGE VALVE (V3).
5. OPEN LIQUID VALVE ON THE RECOVERY TANK.
OPERATION
1. TURN POWER ON AND PRESS START BUTTON.
2. SLOWLY OPEN INLET VALVE (V1).
SHUT DOWN
1. CLOSE INLET VALVE (V1) ONCE DESIRED VACUUM IS ACHEIVED.
2. CLOSE LIQUID VALVE ON RECOVERY TANK.
3. CLOSE DISCHARGE VALVE (V3).
4. TURN POWER SWITCH OFF.